Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | MICRO SURGERY |
Categories | Holding Instruments |
Material Grade | STAINLESS STEEL 316 |
Material | Stainless Steel |
Size/Dimension | 80 MM X 100 MM |
Brand | O.P CHADDA (INDIA) |
Features | SAFETY OF MICRO INSTRUMENTS |
Model Name/Number | BEAKER |
Usage | Hospital,Clinic |
Type | CYLINDRICAL |
Additional Information:
Product Details:
Minimum Order Quantity | 2 Piece |
Categories | Holding Instruments |
Material Grade | SS304 |
Model Name/Number | Single and Double |
Usage/Application | Hospital |
Brand | O.P CHADDA (INDIA) |
Finishing | MATT and BLACK Finish |
Grade | 304 |
Kit Contains | Single pair or double |
Material | Stainless Steel |
Size/Dimension | As per the picture |
Micro vascular clamps, single and double, S&T pattern, matt finish.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | ENT Surgery |
Categories | CRUSHING |
Material Grade | 304 |
Material | Stainless Steel |
Usage | Hospital, Clinic |
Application | ENT Surgery |
Type | Cottle Cartilage |
Additional Information:
IKUTA Vessel Approximator Vascular Micro Surgical Clamps
Vascular clamps are often used during microsurgical anastomosis of a vessel. The double clamp system is widely used nowadays. By holding both ends of the vessel, this device provides good approximation, a tension-free anastomosis, and easy rotation of the vessel from front to back.
This device can be used to anastomose vessels ranging from 0.5 to 5.0 mm, without inflicting injury on the vessel wall.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Set |
Material | Stainless Steel |
Usage/Application | Micro surgery |
Disposable Or Reusable | Reusable |
Brand | O.P CHADDA (INDIA) |
Usage | Hospital, Clinic |
Application | Surgery |
Type | Non-Disposable |
Additional Information:
Product Details:
Minimum Order Quantity | 6 pair |
Material | Stainless Steel |
Brand | O.P CHADDA (INDIA) |
Disposable Or Reusable | REUSABLE |
Color | MATT FINISH |
The Best has become even Better !!
Slippage
The flat and non-serrated Ultra-Grip surface of these clamps ensures that the pressure is spread evenly over the entire area of the vessel wall. This helps you avoid over-pressure peaks, which may easily lead to trauma of the vessel interior.
Clinical Micro Clamps by CHADDA SURGICALS Clamp Security Precisely calibrated closing force, which is 100% quality controlled and inspected, with a secure working grip surface, providing impressive security in use, against both slippage and leakage. CHADDA'S clinical micro clamps are the gentiest and least traumatic of all small vessel clamps. Care of Clamps Micro clamps are prone to damage from the accumulation of blood clotting in tight places. With proper care and cleaning, this can be avoided. Blood should not be allowed to dry on the clamps during surgery. For cleaning after surgery, we recommend immersion for 30 minutes in hemolytic cleaning solution. When immersing the clamps, hold them open for a moment to wet the inner surfaces. Be sure to slide approximator clamps along the bar, back and forth a few times, to remove any accumulated debris from the sliding units. After immersion, rinse vigorously with a fine, high-pressure water jet to remove any blood residue from spring interspaces, sliding units and suture cleats. Applying the Clamps RD and HD clamps are designed to be applied by hand. Their broad, corrugated gripping surfaces make this easy. The three smaller sizes, B-1, B-2, and B-3, are designed to be applied with the clamp applicator forceps. The forceps are direct acting. When the forceps are squeezed, the clamp opens. When held in the forceps, the clamp can be manipulated firmly in any plane without the danger of slipping or falling out. Clamp applicator forceps are available without a lock. Disinfection For the disinfecting process, we recommend using a cycle with the highest temperatures (approximately 93º C). Sterilization In general, you should follow your institution's set guidelines and procedures when sterilizing microsurgical instruments. The most common form of sterilization is steam autoclaving. Microsurgical instruments should be sterilized in their own case. We recommend autoclaving your CHADDA instruments in saturated steam, at a minimum of 134º C, for 5-18 minutes. Please note Do not use a clamp on a vessel below the recommended diameter range. Use of any clamp on a vessel too small will result in unacceptably high pressure, and risk of vessel damage. Chadda Surgicals Whats App : +919819691699 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Country of Origin | Made in India |
Question | 15 cm long |
Micro needle holder, 15cm with lock, Parrot beak tip. O.P CHADDA (INDIA) Make. Have same without lock also.
Product Details:
Minimum Order Quantity | 1 Piece |
Type | Micro surgery vessel dilating forceps |
Material | Stainless Steel |
Usage/Application | Hospital |
Micro Vessel dilator, 0.2 mm tip, Matt Finish. Made from Original sample of S&T.